Installation: Power and Ground Connection
6881086C22-B 7
Power and Ground 
Connection
General All Consolettes should have a separate AC power circuit with proper current 
and voltage for Consolette operation. Refer to the specifications section in the 
front of this manual for AC requirements of each model. The power lines should 
be installed in accordance with local electrical codes. A substantial earth 
ground must be provided in a straight line close to the ground terminal provided 
on the Consolette. DO NOT consider an electrical output box as a substantial 
earth ground. See “Lightning and Surge Suppression” on page ix for additional 
grounding recommendations.
The AC power line leading to the selected site for the Consolette may be 
installed prior to installation of the Consolette itself.
AC Power Input
Figure 3.  Power Supply VAC-Select Switch
NOTE: Replacement 115 VAC power cords may be ordered from 
Motorola as kit number HLN6282A.
Even if a three-wire grounding AC power source is 
available, the radio equipment must be grounded 
separately to prevent electrical shock hazards and 
provide lightning protection.
!
W A R N I N G
!
The Consolette is shipped standard from the 
factory for operation from a 115 VAC power 
source. For 230 VAC operation, remove the 
Consolette top cover (see “Disassembly and 
Reassembly” on page 38) and slide the AC power 
selector switch, located on the Consolette power 
supply, to the 230 VAC position. Install the 
appropriate AC power connector on the end of the 
115 VAC power cord provided with the Consolette.
!
W A R N I N G
!
VAC-Select Switch