4 DIAGNOSTICS
28
Renewable Security
The renewable security system includes a TVPC card that returns the security status
to current.
The Renewable Security fields are:
Field Description
TVPC
Required /
Not
Required
Indicates whether further operation of the set-top requires the TVPC
Crypto Lists the current mode as displayed on the CRYPTO OSD (Stand Alone, Support, or Not
Mated)
Status Indicates the TVPC status with the following variables:
OSD Description
00 OK
01 TVPC communication problem
02 TVPC required
03 Validator does not match between GK and TVPC
04 Invalid unit key number
05 Old TVPC unit address
0a TVPC not mated
0b TVPC/base module unit address mismatch
0c New TVPC, but wrong version number
0d TVPC unit address mismatch
Version Indicates the version of renewable security being used