Specifications
Getting Started 1-3
Introduction
The DC600 portal system is a fully assembled turn-key solution that uses Radio Frequency Identification (RFID) for asset identification
and tracking goods movement in manufacturing plants, cargo logistics, distribution centers, warehouses, and stores.
The DC600 includes an integrated RFID reader and high-performance antennas for fast, accurate reading of RFID tags. All internal
antenna-to-reader connections are included to reduce procurement time and installation effort. The DC600 can leverage two or more
antennas for each dock door to increase coverage.
The DC600 can sustain minor non-direct pallet impact. Its bolted installation makes it robust for industrial environments. The DC600
is dust and water resistance to ensure reliable service in harsh environments and can work in temperatures between -4
o
F to
+122
o
F (-20
o
C to 50
o
C) and humidity of 5% to 95% RH.
Figure 1-1. DC600 Parts
Facility Power Requirements
The DC600 portal system requires the following power input requirements:
1. A dedicated AC circuit is recommended (but not required), 4.5 amps is the maximum current.
2. AC voltage must be within the 90VAC - 264VAC range.
3. AC power cycle requirements must be within 47Hz to 63Hz.
4. An external power switch that disconnects all poles is recommended. The power switch for the DC600 is located inside of
the Cable Entry Module.
Electronics Module
RFID Reader
Reader Status Indicator Lights
Portal Status
Indicator Lights
Motion Sensor
Antennas
Antennas
Cable Entry Module