User`s guide
CPU32 Emulation 185
Chapter 11: Troubleshooting the Emulator
Problems with the Emulation Probe
To run complete performance verification tests
for an emulation probe
The LAN tests can only be executed through the RS-232 port. The
remainder of this section assumes that the tests are being run from a
terminal emulator connected to the RS-232 port.
1
Disconnect the 50-pin cable from the emulation probe, and plug
the emulator loopback test board (HP part number E3496-
66502) directly into the emulator. Do not plug anything into the
other end of the emulator loopback test board.
On a good system, the RESET LED will light and the BKG and USER
LEDs will be out.
2
Connect a coaxial cable between BREAK IN and TRIGGER OUT.
3
Set all of the switches to CLOSED.
This is standard RS-232 at 9600 baud which can be connected directly
to a 9 pin RS-232 interface that conforms to the IBM PC-AT 9 pin
standard.
4
Use a terminal emulator to connect to the emulation probe.