178 CPU32 Emulation
Chapter 11: Troubleshooting the Emulator
Problems with the LAN Interface (Emulation Probe Only)
❏
Use a serial connection to run the LAN performance verification tests (see
page 174).
If you have LAN connection problems
❏
If the emulation probe does not accept commands from the
HP 16600A/700A:
1. Check that switch S1 is "0" (attached to LAN, not RS-232).
2. Check that switch S5 is in the correct position for your LAN interface
(either 10BASE2 or 10BASE-T).
(Remember: if you change any switch settings, the changes do not take
effect until you cycle power.)
❏
If the emulation probe still does not respond, you need to verify the IP
address and gateway mask of the emulation probe. To do this, connect the
emulation probe to a terminal or terminal emulator (see page 42), change
the switch settings so it is connected to RS-232, and enter the "lan"
command. The output looks something like this:
...lan -i 15.5.24.116
...lan -g 15.5.23.1
...lan -p 6470
...Ethernet Address : 08000909BAC1
"lan -i" shows the internet address is 15.5.24.116 in this case. If the
Internet address (IP) is not what you expect, you can change it with
the ’lan -i >’ command.
"lan -g" shows the gateway address. Make sure it is the address of your
gateway if you are connecting from another subnet, or 0.0.0.0 if you are
connecting from the local subnet.
"lan -p" shows the port is 6470.