User`s guide

176 CPU32 Emulation
Chapter 11: Troubleshooting the Emulator
Problems with the Emulation Module
If a performance verification test fails
Details of the failure can be obtained through using a -v option (“verbose”
level) of 2 or more.
Check that the loopback test board is connected.
If the problem persists, contact HP for assistance.
To execute tests 3, 4, and 5 only for 2 cycles:
pv -t3-5 2
The results on a good system with the loopback test board
connected, are as follows:
M>pv 1
Testing: HPE3499C Series Emulation System
Test 1: Powerup PV Results Passed!
Test 2: Target Probe Feedback Test Passed!
Test 3: Boundary Scan Master Test Passed!
Test 4: I2C Test Passed!
Test 5: Data Lines Test Passed!
Number of tests: 1 Number of failures: 0
Copyright (c) Hewlett-Packard Co. 1987
All Rights Reserved. Reproduction, adaptation, or translation without
prior
written permission is prohibited, except as allowed under copyright laws.
HPE3499C Series Emulation System
Version: A.07.53 26Feb98
Location: Generics
HPE3490A Motorola CPU16/32 BDM Emulator
Version: A.02.05 26Feb98
M>