User`s guide

132 CPU32 Emulation
Chapter 7: Using the Emulator with a Debugger
Using the Software Development Systems debugger
Error conditions
"!ERROR 800! Invalid command: bcast" usually means that there is not
a target interface module (TIM) connected to the emulator or the
emulator does not have firmware for the CPU32 family. Verify that the
emulator is connected to the target. Next, go to the system window of
the logic analyzer interface and verify that the Emulation Module icon
(stop-light) is described as a Motorola CPU16/32 BDM Emulator. If it is
not, follow the steps on page 147 to update the firmware in the
emulation module.
"command socket connection failed: WSAECONNREFUSED: connection refused"
usually means the emulation module is not at port #6470 on the Logic
Analysis System. See step 2 of the getting started section above.
"unrecognized hostname"
usually means that the debugger is unable to establish communication
with the emulator. Verify communication to the emulation module by
doing a ping to the logic analyzer. If you are unable to ping the logic
analyzer refer to page 172 for more information.
See Also
The SDS web site: hhttp://www.sdsi.com
The SDS SingleStep Users Guide.
The configuration section beginning on page 75 for more information
on configuration options and the "cf" command.