Specifications

4 Filtering Trace
4.3 Filtered Trace Limitations
67
4
Trace Sync Broadcast
This is an internal Wind River option.
Trace Trigger
This option is similar to Trace Off. The only difference is that once it hits the trigger
and stops tracing, the trace will remain stopped until the next
GO command is
issued. Use the Post Trigger Counter to control the amount of trace captured after
the address match.
This option can also be set using low-level commands. At the
>BKM> prompt in
the OCD Command Shell, use the following commands:
Syntax:
IHBC addr TRIG
Set PT value
or
IHBD addr data TRIG
Set PT value
value -- limit is FFFF.
4.3 Filtered Trace Limitations
4.3.1 Filtered Trace Limitations For Wind River Trace With AMCC 405 and 440
Processors
The filtered trace options that are supported with the AMCC 405 and 440
processors are as follows:
One Trace On (TE)
One Trace Off (TD)
One Trace On (TE) and one Trace Off (TD)
One To Four Report Only (MK)