MOTOROLA Chapter 9. Clock Module 9-17
Functional Description
A special loss-of-clock condition occurs when both the reference and the PLL fail. The
failures may be simultaneous, or the PLL may fail first. In either case, the reference clock
failure takes priority and the PLL attempts to operate in SCM. If successful, the PLL
remains in SCM until the next reset. If the PLL cannot operate in SCM, the system remains
static until the next reset. Both the reference and the PLL must be functioning properly to
exit reset.
9.7.4.11 Loss of Clock in Stop Mode
Table 9-10 shows the resulting actions for a loss of clock in Stop Mode when the device is
being clocked by the various clocking methods.
Table 9-10. Stop Mode Operation (Sheet 1 of 5)
MODE
In
LOCEN
LOCRE
LOLRE
PLL
OSC
FWKUP
Expected
PLL
Action at
Stop
PLL Action
During Stop
MODE
Out
LOCKSS
LOCK
LOCS
Comments
EXT X X X X X X — — EXT 0 0 0
Lose reference
clock
Stuck ———
NRM 0 0 0 Off Off 0 Lose lock,
f.b. clock,
reference
clock
Regain NRM ‘LK 1 ‘LC
No regain Stuck — — —
NRM X 0 0 Off Off 1 Lose lock,
f.b. clock,
reference
clock
Regain clocks, but
don’t regain lock
SCM–>
unstable
NRM
0–>‘L
K
0–>1 1–>‘L
C
Block LOCS and
LOCKS until
clock and lock
respectively
regain; enter
SCM regardless
of LOCEN bit
until reference
regained
No reference clock
regain
SCM–> 0–> 0–> 1–> Block LOCS and
LOCKS until
clock and lock
respectively
regain; enter
SCM regardless
of LOCEN bit
No f.b. clock
regain
Stuck ———