User guide

45 Mbps Backhaul User Guide
Issue 3, December 2004 Page 85 of 113
8.4 EMC Immunity Compliance
Top-level Specification ETSI 301-489.
Specification
Comment
EN 55082-1 Generic EMC and EMI
requirements for Europe
EN 61000-4-2: 1995 Electro Static Discharge
(ESD), Class 2, 8 kV air, 4 kV contact discharge
EN 61000-4-3: 1995 ENV50140: 1993 (radiated
immunity) 3 V/m
EN 61000-4-4: 1995 (Bursts/Transients), Class
4, 4 kV level (power lines AC & DC)
Signal lines @ 0.5 kV open circuit
voltage.
EN 6100045:1995, (Surge Immunity)
Requires shielded connection to users
network
EN 61000-4-6: 1996 (Injected RF), power line,
Class 3 @ 10 V/m
Signal lines, Class 3 @ 3 V RMS un-
modulated.
8.5 Radio Certifications
Region
Specification (Type Approvals)
USA
FCC Part 15.247
UK
VNS 2107
Eire
ComReg 03/42
8.6 Environmental Specifications
Category
Specification
Temperature
ODU: -40°F(-40°C) to 140°F (+60°C)
PIDU & PSU: 32°F(0°C) to 104
o
F(+40°C)
Wind Loading
151mph Max (242kph)
Humidity
100% Condensing