User guide
Understanding Canopy Networks March 2005
Through Software Release 6.1
Issue 1 Page 53 of 425
Canopy System User Guide
5.7.2 Cluster Management Products
Table 14: CMM2 specifications and limitations
Specification or Limitation Canopy System Range
Max length from Cluster Management
Module to any radio
328 cable feet (100 meters)
Max length from Cluster Management
Module to GPS antenna
100 cable feet (30.5 meters)
Dimensions
17.00” H x 12.88” W x 6.50” D
(43.18 cm H x 32.72 cm W x 16.51 cm D)
Weight 25.0 lbs. (11.3 kg)
Operation Temperature -40°F to +131°F (-40°C to +55°C)
Overall Meets CE IP44 according to EN60529:2000
AC Input Voltage and Frequency
100 V – 240 V~, 0.7 A – 0.35 A, settable to either 230 V or 115 V
nominal input.
50 Hz – 60 Hz
Note: Applying 230 V to a unit that is set to 115 V may damage
the unit.
AC Input Power
Nominal 66 watts, max 92 watts with 8 modules connected to the
CMM at max cable length.
24-V DC Input Voltage 18 to 32 V DC, measured at CMM
24-V DC Input Power
Nominal 60 watts. Maximum 84 watts with 8 modules connected
to the CMM at maximum cable length. 9A inrush upon start-up.
24-V DC Usage
If using a typical “24V +/-5%” power supply, ensure that CMM is
within 400 cable feet (120 m) of the power supply. Use minimum
12 AWG (4 mm
2
) copper wire.
12-V DC Input Voltage 11.5 to 32 VDC, measured at CMM
12-V DC Usage
If using a 12V power source (typically an automobile battery in a
test or emergency situation), use 12 AWG (4 mm
2
) wire between
the power supply and the CMM, ensure that the CMM is within 10
cable feet (3 m) of the power supply, and ensure the modules are
within 20 cable feet (6 m) of the CMM.
Ethernet, GPS Sync, and GPS Coax
Cables
The use of cables that conform to the operational temperature of
the product as well as being UV light protected is mandatory.