User guide

March 2005 Canopy System Reference Information
Through Software Release 6.1
Page 398 of 425 Issue 1
Canopy System User Guide
config modify esn esn cir [lpruldr|lprdldr|hpruldr|hprdldr|enablehpr] value
Set or reset the specified CIR parameter for the ESN to the specified value.
RULES:
lpruldr
Low Priority Uplink CIR in the range 0 to 20000 kbps.
lprdldr
Low Priority Downlink CIR in the range 0 to 20000 kbps.
hpruldr
High Priority Uplink CIR in the range 0 to 20000 kbps.
hprdldr
High Priority Downlink CIR in the range 0 to 20000 kbps.
enablehpr
Hi Priority Channel parameter as 1 (enable) or 0 (disable).
config modify esn esn vlan [alllearn|allframe|timeout|ingvid|managevid] value
Set or reset the specified VLAN parameter for the ESN to the specified value.
RULES:
alllearn
Dynamic Learning parameter as 1 (enable) or 0 (disable).
allframe
Allow Only Tagged Frames parameter as 1 (enable) or 0 (disable).
timeout
VLAN Aging Timeout parameter in the range 5 to 1440 minutes.
ingvid
Untagged Ingress VID parameter in the range 1 to 4095.
managevid
Management VID parameter in the range 1 to 4095.
config add vlanmember esn esn vlanid vlanid
Associate esn with the VLAN vlanid.
RULES:
vlanid
1 to 4095
config delete vlanmember esn esn vlanid vlanid
Dissociate esn from the VLAN vlanid. Rules are as defined above.
CAUTION!
The following command erases all data in the remote database before
the copy execution.
config copy to database ip user password
Copy configuration data from port on the network element that is identified by ip into the
database. To do so, identify the user and password that the database has stored.
NOTE: This command is deprecated in BAM Release 2.0 and later releases.