User guide
March 2005 Managing Your Canopy Network
Through Software Release 6.1
Page 294 of 425 Issue 1
Canopy System User Guide
− hardware compatibility. For example, where a CMMmicro is deployed.
− the value of each configurable parameter. Whether all are compatible in the
new destination.
◦ remembering to add the redeployed SM to the ESN data table in the BAM
server(s).
21.3.1 Wiring to Extend Network Sync
The following procedure can be used to extend network sync by one additional hop, as
described under Passing Sync in an Additional Hop on Page 70. Where a collocated
module receives sync over the air, the collocated modules can be wired to pass the sync
as follows:
Procedure 39: Extending network sync
1. Connect the GPS Utility ports of the collocated modules using a sync cable with
RJ-11 connectors.
2. Set the Sync Input parameter on the Configuration page of the collocated AP or
BH timing master to Sync to Received Signal (Timing Port).
3. Set the Frame Timing Pulse Gated parameter on the Configuration page of the
collocated SM or BH timing slave to Enable.
NOTE: This setting prevents interference in the event that the SM or BH timing
slave loses sync.
end of procedure