User guide

March 2005 Building Your Canopy Network
Through Software Release 6.1
Page 274 of 425 Issue 1
Canopy System User Guide
Figure 107: Audible Alignment Tone kit and example tone
Move the module slightly until you hear the highest pitch and highest
volume.
Continue to move the module slightly until you hear the tone
interruptions, if possible.
24. On the computer, in the RSSI Only Mode field, click Enabled.
25. Click Enable Aiming Mode.
26. Simultaneously, begin to
move the module slightly in the vertical plane.
on the computer, click Enable Aiming Mode frequently to refresh the page
as the module moves (or select the auto-refresh option for this web page).
monitor the screen for a simultaneous RSSI level of greater than 700, jitter
value between 0 and 4 in Release 4.0 and later releases or between 5 and 9
in any earlier release, and efficiencies greater than 90% for both the uplink
and the downlink.
27. When the RSSI level is greater than 700, stop the movement of the module and
click Disable in the RSSI Only Mode field.
28. Access the Status page.
29. Monitor this page for the messages Scanning, Syncing, Registering, Registered,
Alignment.
NOTE: If the SM does not register with the AP, ensure that both modules are
configured to the same color code in the Configuration page of each. In
Release 4.0 and later releases, the Expanded Stats page of the AP provides a
link to the Reg Failed SMs page, where the cause of a registration failure may be
found.
30. Resume slight movements of the module
31. When the best achievable values are simultaneously displayed on the Status
page, lock the module into position.
NOTE: If any of these values is not achieved, the SM may be operational but
manifest occasional problems.
end of procedure