User guide

March 2005 Building Your Canopy Network
Through Software Release 6.1
Page 272 of 425 Issue 1
Canopy System User Guide
Stainless steel
hose clamps
Reflector dish arm
Figure 105: SM attachment to reflector arm
6. Use stainless steel hose clamps or equivalent fasteners to lock the SM into
position.
Computer
outside wall
Ethernet cable
300SS
ground
system
Ethernet cable
10 AWG
CU wire
SM
to NIC
24 VDC to
Canopy
wall adapter
Figure 106: SM and computer wiring
7. Remove the cover of the 300SS Surge Suppressor.
8. With the cable openings facing downward, mount the 300SS to the outside of the
subscriber premises.
9. Using diagonal cutters or long nose pliers, remove the knockouts that cover the
cable openings to the 300SS.
10. Connect an Ethernet cable from the pig tail power adapter to either RJ-45 port of
the 300SS.
11. Connect another Ethernet cable from the other RJ-45 port of the 300SS to the
Ethernet port of the SM.
12. Wrap an AWG 10 (or 6mm
2
) copper wire around the Ground post of the 300SS.
13. Tighten the Ground post locking nut in the 300SS onto the copper wire.