User guide

Building Your Canopy Network March 2005
Through Software Release 6.1
Issue 1 Page 267 of 425
Canopy System User Guide
NOTE: Instructions for installing a Canopy Surge Suppressor are provided in
Procedure 32 on Page 271.
13. Connect GPS coaxial cable to the N-connector on the outside of the CMM2. See
Figure 48 on Page 134.
14. Connect AC or DC power to the CMM2, consistent with Figure 102 on Page 265.
When power is applied, the following indicators are lighted:
the power LED on the Ethernet switch
the green LED on the circuit board, as shown in Figure 104.
Figure 104: Port indicator LED on Ethernet switch
15. Verify that each port indicator LED on the Ethernet switch is lit (each AP or BH is
reliably connected to the Ethernet switch).
16. Replace the base cover on each AP or BH.
17. Close and lock the CMM2.
end of procedure
19.5.5 Verifying CMM2 Connections
To verify the CMM2 connections after the APs and or BHs have been installed, perform
the following steps:
Procedure 27: Verifying CMM2 Connections
1. Access the web-based interface for each AP or BH by opening
http://<ip-address
>, where the <ip-address> is the address of the individual
module.
2. In the Status page, verify that the time is expressed in GMT.
3. In the menu on the left-hand side of the web page, click on GPS Status.