User guide

Building Your Canopy Network March 2005
Through Software Release 6.1
Issue 1 Page 255 of 425
Canopy System User Guide
LAN1 Network Interface Configuration, Gateway IP Address
Enter the appropriate gateway for the BHS to communicate with the network. The default
gateway is 169.254.0.0.
The IP Configuration page also provides the following buttons.
Save Changes
When you click this button, any changes that you made on the IP Configuration page are
recorded in flash memory. However, these changes do not apply until the next reboot of
the module.
Undo Saved Changes
When you click this button, any changes that you made but were not committed by a
reboot of the module are undone.
Set to Factory Defaults
When you click this button, all configurable parameters on all configurable pages are
reset to the factory settings.
Reboot
When you click this button
1. the module reboots.
2. any changes that you saved by a click of the Save Changes button are
implemented.
Whenever you change a parameter in the IP Configuration page, the system highlights
the Reboot button as a reminder that a reboot (in addition to a save) is required to
implement the changes.
18.6 ADJUSTING TRANSMITTER OUTPUT POWER
Authorities may require transmitter output power levels to be adjustable and/or lower than
the highest that a module produces. Canopy 2.4-GHz modules with Release 4.2.7 or later
and 5.4-GHz modules include a Configuration page parameter to reduce power on an
infinite scale to achieve compliance.
The professional installer of Canopy equipment has the responsibility to
maintain awareness of applicable regulations.
calculate the permissible transmitter output power for the module.
confirm that the initial power setting is compliant.
confirm that the power setting is compliant following any reset of the module to
factory defaults.