User guide

March 2005 Building Your Canopy Network
Through Software Release 6.1
Page 254 of 425 Issue 1
Canopy System User Guide
18.5.2 IP Configuration Page of the BHS
An example of the BHS IP Configuration page is displayed in Figure 95.
Figure 95: IP Configuration screen, BHS
You may set the following IP Configuration page parameters.
LAN1 Network Interface Configuration, IP Address
Enter the non-routable IP address to associate with the Ethernet connection on this BHS.
(The default IP address from the factory is 169.254.1.1.) If you set and then forget this
parameter, then you must both
1. physically access the module.
2. use an override plug to electronically access the module configuration
parameters at 169.254.1.1. See Overriding Forgotten IP Addresses or
Passwords on AP, SM, or BH on Page 302.
RECOMMENDATION:
Note or print the IP settings from this page. Ensure that you can readily
associate these IP settings both with the module and with the other data
that you store about the module.
LAN1 Network Interface Configuration, Subnet Mask
Enter an appropriate subnet mask for the BHS to communicate on the network. The
default subnet mask is 255.255.255.0. See Allocating Subnets on Page 123.