User guide

March 2005 Building Your Canopy Network
Through Software Release 6.1
Page 226 of 425 Issue 1
Canopy System User Guide
Save Changes
When you click this button, any changes that you made on the NAT Configuration page
are recorded in flash memory. However, these changes do not apply until the next reboot
of the module.
Undo Saved Changes
When you click this button, any changes that you made but were not committed by a
reboot of the module are undone.
Set to Factory Defaults
When you click this button, all configurable parameters on all configurable pages are
reset to the factory settings.
Reboot
When you click this button
1. the module reboots.
2. any changes that you saved by a click of the Save Changes button are
implemented.
Whenever you change a parameter in the NAT Configuration page, the system highlights
the Reboot button as a reminder that a reboot (in addition to a save) is required to
implement the changes.
18.2.6 NAT/Advanced Network Configuration Page of the SM with NAT Enabled
Examples of SM NAT Configuration screens when NAT is enabled are displayed in
Figure 85 for the NAT with DHCP Client and DHCP Server implementation.
Figure 86 for the NAT with DHCP Client implementation.
Figure 87 for the NAT with DHCP Server implementation.
Figure 88 for the NAT without DHCP implementation.