User guide

March 2005 Building Your Canopy Network
Through Software Release 6.1
Page 204 of 425 Issue 1
Canopy System User Guide
18.1.2 IP Configuration Page of the AP
An example of the AP IP Configuration screen is displayed in Figure 74.
Figure 74: IP Configuration screen, AP
You may set the IP Configuration page parameters as follows.
LAN1 Network Interface Configuration, IP Address
Enter the non-routable IP address to associate with the Ethernet connection on this AP.
(The default IP address from the factory is 169.254.1.1.) If you set and then forget this
parameter, then you must both
1. physically access the module.
2. use an override plug to electronically access the module configuration
parameters at 169.254.1.1. See Overriding Forgotten IP Addresses or
Passwords on AP, SM, or BH on Page 302.