The Configuration web page contains all of the configurable parameters that define how
the module operates. The first line of information on the Configuration screen echoes the
Device Type from the Status web page.
You may set the Configuration page parameters as follows.
Sync Input
Specify the type of synchronization for this AP to use:
◦ Select Sync to Received Signal (Power Port) to set this AP to receive sync
from a connected CMMmicro.
◦ Select Sync to Received Signal (Timing Port) to set this AP to receive sync
from a connected CMM2, an AP in the cluster, an SM, or a BH timing slave.
◦ Select Generate Sync Signal where the AP does not receive sync, and no other
AP or BHM is active within the link range. For link range information, see
− AP-SM Link Distances on Page 73.
− BH-BH Link Distances on Page 76.
Link Negotiation Speeds
Specify the type of link speed for the Ethernet connection. The default for this parameter
is that all speeds are selected. The recommended setting is a single speed selection for
all APs, BHs, and SMs in the operator network.
RF Frequency Carrier
Specify the frequency for the module to transmit. The default for this parameter is None.
(The selection labeled Factory requires a special software key file for implementation.)
For a list of channels in the band, see Considering Frequency Band Alternatives on
Page 100.