User guide

March 2005 Building Your Canopy Network
Through Software Release 6.1
Page 178 of 425 Issue 1
Canopy System User Guide
IMPORTANT!
Changes that are made to the following parameters become effective
when you click the Save Changes button:
Port Configuration
Description
Power Port Control
Webpage Auto Update
When these parameters listed above have become effective, if you click
the Undo Saved Changes button, the previous values are not restored.
Changes that are made to all other parameters become effective only after all of the
following have occurred:
you have clicked the Save Changes button.
you click the Reboot button.
the CMMmicro reboots.
Procedure 22: Setting CMMmicro parameters for test
To continue the test setup, configure
1. the GPS Timing Pulse parameter.
2. the Lan1 IP parameter.
3. the Lan1 Subnet Mask parameter.
4. the Default Gateway parameter.
5. the Port Power Control parameter.
end of procedure
GPS Timing Pulse
Select Master. (Slave is for future use.)
IMPORTANT!
If the GPS Timing Pulse is set to Slave, the CMMmicro GPS receiver is
disabled.