User guide
Building Your Canopy Network March 2005
Through Software Release 6.1
Issue 1 Page 143 of 425
Canopy System User Guide
The format for entry is
Time hh:mm:ss
Date mm/dd/yyyy
where
hh
represents the two-digit hour in the range 00 to 24
mm
represents the two-digit minute
ss
represents the two-digit second
mm
represents the two-digit month
dd
represents the two-digit day
yyyy
represents the four-digit year
Proceed with the test setup as follows.
Procedure 8: Setting up the SM for test
1. Enter the appropriate information in the format shown above.
2. Click the Set Time and Date button.
NOTE: The time displayed at the top of this page is static unless your browser is
set to automatically refresh.
3. In one hand, securely hold the top (larger shell) of the SM. With the other hand,
depress the lever in the back of the base cover (smaller shell). Remove the base
cover.
4. Plug one end of a CAT 5 Ethernet cable into the SM.
5. Plug the other end of the Ethernet cable into the jack in the pig tail that hangs
from the power supply.
6. Roughly aim the SM toward the AP.
WARNING!
From this point until you remove power from the SM, stay at least as far
from the SM as the minimum separation distance specified under
Preventing Overexposure to RF on Page 127.
7. Plug the power supply into an electrical outlet.
8. Repeat the foregoing steps for each SM that you wish to include in the test.
9. Back at the computing device, on the left side of the AP Time & Date page, click
the Sessions button.
RESULT: The AP responds by opening the Sessions page.
end of procedure