Troubleshooting guide

BSR Troubleshooting Guide
2-32
Table 2-8 describes the possible display states of these LEDs during operation.
Upstream and Downstream Port LEDs
The BSR 1000 downstream port and each upstream port has two LEDs to indicate
their operational status. These LEDs are located near the center of the BSR 1000
front panel and are labeled Status and Alarm.
Table 2-8 BSR 1000 System LED Display States
Fail Status Alarm Interpretation
Off Green Off Normal operating status.
Off Green Red Failure. BSR 1000 is operating with an alarm
condition.
Note: This LED sequence occurs when an alarm
condition is detected on individual upstream and
downstream ports.
Red Off Off Fuse failure possibly indicating a hardware
failure.
Red Off Red Failure. BSR 1000 is not operating.
Red Green Red Reset. Reset button was pressed and the
BSR 1000 is starting its boot process.
Off Off Off BSR 1000 is not receiving power or is switched
Off.