System information

BSR 64000 Configuration and Management Guide
14-18
MOT(config-if)#no pos report [all | b1-tca | b2-tca | b3-tca | lais | lrdi | pais |
plop | prdi | rdool | sd-ber | sf-ber | slof | slos]
Table 14-6 describes the SONET reports that you can configure:
Setting the Line Alarm Indication Signal
The pos ais-shut command controls whether an Alarm Indication Signal - Line
(AIS-L) is sent to the far end SONET device when the POS interface is placed in an
administrative shutdown state. To configure whether an Alarm Indication Signal-Line
(AIS-L) is sent when a POS interface is shut down, use the pos ais-shut command in
POS Interface Configuration mode as shown below:
MOT(config-if)#pos ais-shut
Table 14-6 SONET Alarm Report Selections and Descriptions
Alarm Report Description
all All possible alarm reporting
b1-tca B1 BER TCA errors
b2-tca B2 BER TCA errors
b3-tca B3 BER TCA errors
lais Line alarm indication signal
lrdi Line remote defect indicator
pais Path alarm indication signal
plop Path loss of pointer
prdi Path remote defect indicator
rdool Remote data out of lock
slof Section loss of frame error
slos Section loss of signal error
Note: If the far end SONET device has Automatic Protection Switching (APS)
configured, an APS switch can be forced by using the pos ais-shut
command.