System information
BSR 64000 Configuration and Management Guide
14-16
Table 14-5 describes the SONET alarms that can be configured on the POS module:
Setting Alarm Thresholds
Use the SONET alarm thresholds discussed in this section to evaluate network
performance. Alarm thresholds define the Bit Error Rate (BER) threshold values for
specific control bits in SONET frames. The default SONET alarm thresholds are
adequate for most POS installations. Refer to Table 14-10 for more information on
each alarm threshold.
Follow these steps to set SONET alarm thresholds:
1. To configure the BER threshold for the b1 threshold crossing alarm (TCA), use
the pos threshold b1-tca command in Interface Configuration mode as shown
below:
Table 14-5 SONET Alarm Commands
Command Description Default Value
pos threshold
b1-tca
The BER threshold for the
b1 threshold crossing
alarm (TCA)
4 (10E-4
Rate)
3 to 9 (10E-3 to 10E-9
Rate)
pos threshold
b2-tca
The BER threshold for the
b2 threshold crossing
alarm (TCA)
4 which is
10E-4 Rate.
3 to 9 (10E-3 to 10E-9
Rate)
pos threshold
b3-tca
The BER threshold for the
b3 threshold crossing
alarm (TCA)
4 which is
10E-4 Rate.
3 to 9 (10E-3 to 10E-9
Rate)
pos report SONET alarm reporting No reports
are set.
all, b1-tca, b2-tca,
b3-tca, lais, lrdi,
pais, plop, prdi,
rdool, sd-ber, sf-ber,
slof, slos
pos ais-shut Controls whether an Alarm
Indication Signal - Line
(AIS-L) is sent to the far
end SONET device when
the POS interface is
placed in an
administratively shutdown
state
disabled enabled or disabled