System information

Configuring Packet Over SONET
14-15
string is a text string containing the 62 byte sequence. The remaining 2 bytes
are automatically set to CR/LF for framing purposes.
8. To configure the j1 byte as a single hex byte, use the pos flag j1 command in
Interface Configuration mode, as shown below:
MOT(config-if)#pos flag j1 <hexnum>
where:
hexnum is the hexadecimal value for the j1 byte.
9. The s1 byte identifies the timing source for SONET frame synchronization. To set
the hexadecimal value for the s1 byte, use the pos flag s1 command in Interface
Configuration mode, as shown below:
MOT(config-if)#pos flag s1 <hexnum>
where:
hexnum is the hexadecimal value for the s1 byte
.
Configuring SONET Alarms
The following sections discuss SONET alarm thresholds, alarm reports, and alarm
indicators:
Setting Alarm Thresholds
Setting Alarm Reporting
Setting the Line Alarm Indication Signal
Note: Only the lower four bits of the s1 byte are actually configured.