System information

BSR 64000 Configuration and Management Guide
6-96
2. To specify the flap list insertion time, use the cable flap-list insertion-time
command in Global Configuration mode, as shown below:
MOT(config)#cable flap-list insertion-time <1-86400>
where:
1-86400 is the flap list insertion time, expressed in seconds. The default flap
list insertion time is 60.
3. Use the cable flap-list power-adjust threshold command in Global
Configuration mode to specify the power adjustment threshold value between 0
to 2 dBmV, as shown below. The power adjustment threshold causes a flap-list
event to be recorded when the threshold is exceeded:
MOT(config)#cable flap-list power-adjust threshold {<1-10>}
where:
1-10 is the power adjustment threshold value, expressed in dB.
Note: Motorola recommends that you do not change the power adjustment
threshold from the default value, which is 2 dbmV. Ensure that you evaluate
the need to enable this function before applying it to your network. A power
adjustment threshold of less than 1 dBmV may cause excessive flap list
event recording.