System information

Configuring the CMTS
6-51
2. Use the cable privacy tek life-time command in Interface Configuration mode to
configure the global TEK lifetime value, as shown below:
MOT(config-if)#cable privacy tek life-time {<30-604800>}
where:
30-604800 is the TEK life-time value in seconds (the maximum value is 7
days).
To restore the default, use the no cable privacy tek life-time command in
Interface Configuration mode, as shown below:
MOT(config-if)#no cable privacy tek life-time {<30-604800>}
To set an individual CM grace-time TEK value for Baseline Privacy, use the
cable privacy cm-tek grace-time command in Interface Configuration mode, as
shown below. Use the no cable privacy cm-tek grace-time command to reset the
default.
MOT(config-if)#cable privacy cm-tek grace-time {<1-8192>
<300-302399>}
where:
1-8192 is the service-id (SID).
300-302399 is the grace-time value, expressed in seconds (5 minutes to 3.5
days).
3. If a new grace-time value is set for one or more CMs, use the cable privacy
cm-tek reset command in Interface Configuration mode to reset the grace-time
CM TEK value, as shown below:
MOT(config-if)#cable privacy cm-tek reset