System information
BSR 64000 Configuration and Management Guide
6-28
where:
NUM is the upstream port number.
To reset the upstream minislot size, use the no cable upstream minislot-size
command in Interface Configuration mode, as shown below:
MOT(config-if)#no cable upstream <NUM> minislot-size [2 | 4 | 8 | 16 | 32
| 64 | 128]
where:
NUM is the upstream port number.
• Issue the cable upstream channel-width command in Interface Configuration
mode to set the upstream channel width in Hertz (Hz), as shown below:
MOT(config-if)#cable upstream <NUM> channel-width [200000 |
400000 | 800000 | 1600000 | 3200000]
where:
NUM is the upstream port number.
To reset the default, use the no cable upstream channel-width command in
Interface Configuration mode, as shown below:
MOT(config-if)#no cable upstream <NUM> channel-width [200000 |
400000 | 800000 | 1600000 | 3200000]
where:
NUM is the upstream port number.
• Use the cable upstream range-backoff command in Interface Configuration
mode to set the start and end upstream range-backoff values for a CM or
re-establish a CM if a power outage occurs, as shown below. If you choose
automatic, the system sets the upstream data-backoff start and end values:
MOT(config-if)#cable upstream <NUM> range-backoff [automatic |
<0-15> | <0-15>]
where:
NUM is the upstream port number.
0-15 is the ranging backoff start value.