System information
BSR 64000 Configuration and Management Guide
4-4
snmp-server notify
{<octet-string>}
{<octet-string>} [inform |
trap] [nonvolitile |
volitile] [active |
not-in-service | <cr>]
Configure the
notification table.
1. Specify the first
octet-string, which
specifies the notification
name.
2. Specify the second
octet-string, which
specifies the notification
tag.
3. Choose whether the
notification messages
sent to the host is a trap
or inform.
4. Choose whether the
message is stored in
nonvolitile and volitile.
5. Set the RowStatus to
active or not-in-service.
RowStatus
is active.
snmp-server
target-addr
{<octet-string>}
{<octet-string>}
{A.B.C.D} udp-port
{<0-65535}
Configuring the
SNMP server
target address
table.
1. Set the first octet-string,
which specifies the
snmpTargetAddr table
name.
2. Configure second
octet-string, which
specifies the
snmpTargetAddrName
(index into
snmpTargetAddrTable).
3. Set the IP address of
the SNMP notification
host.
4. Enter the UDP port
number.
Not
configured
Table 4-1 snmp-server Commands (continued)
Command Description Value Default