System information
BSR 64000 Configuration and Management Guide
3-56
Displaying Module Hardware Information
The show controllers command displays detailed hardware and configuration
information for each module on installed in the BSR 64000 chassis.
• Use the show controllers cable command to display the following CMTS
module information:
MOT#show controllers cable {<x>/<y>} [upstream <port> | downstream
<port> | mac | <cr>]
where:
x is the CMTS module slot number.
y is the cable interface number, which is 0.
UpTime If the system clock has been set using the clock set command, the
UpTime field displays the amount of time that the module has been
operational. The time is expressed in hh:mm:ss format.
LastUpTime If the module is down, the last operational time for the module displays.
Success The module booted successfully.
Failure The module failed the boot process.
Alarms Indicates that alarms are configured for the top and bottom fan trays.
Status An x appears in the status field if a fan tray becomes disabled.
Disabled The disabled column displays no output information at this time.
Priority Both fan trays have a critical priority assigned to them.
Note: Refer to Displaying Physical SONET Link and Alarm Information for
more information about the show controllers pos command.
Table 3-4 BSR 64000 Chassis Status Field Descriptions
Field Description