Technical information
Chapter 3: Electrical and Environmental Specifications
December 15, 2009 G30 - Module Hardware Description 61
Environmental Specifications
Table 3-12 gives the environmental operating conditions of the G30 module.
Caution: Exceeding the values may result in permanent damage to the module.
Application Interface Specifications
Table 3-13 summarizes the DC electrical specifications of the application interface connector
signals.
Important: Interface signals that are not used by the customer application must be left
unconnected. G30 incorporates the necessary internal circuitry to keep unconnected
signal in their default state. Do not connect any components to, or apply any voltage
on, signals that are not used by the application.
Important: Signals that are defined as "Do Not Use", or DNU, must remain externally
unconnected in any case. These signals are reserved for future use.
Figure 3-1 and Figure 3-2 give a brief description of the 70 pins connector and the 81 pin LGA
interface irrespectively for quick integration.
Table 3-12: Environmental Ratings
Parameter Conditions Min Max Unit
Ambient Operating
Temperature
-30 85 °C
Storage Temperature -40 85 °C
ESD
At antenna connector
Contact
Air
At interface pads/con-
nector
± 8
± 15
± 1
KV