Technical information
Chapter 4: Mechanical Specifications
December 15, 2009 G30 - Module Hardware Description 77
Mating Connector
The RF mating connector should be a standard U.FL plug connector or cable assembly, which
corresponds to the G30 U.FL connector specifications.
Only Hirose U.FL mating cable may be mated with G30. A family of Hirose mating cables are
available.
Such a cable assembly example is the Hirose U.FL-LP-040 is U.FL-R-SMT, which is illustrated
in Figure 4-7.
Figure 4-7: U.FL Mating Connector
Rated voltage 60 VAC (rms) - standard receipt (Styles
A, B)
Dielectric
Withstanding
Voltage
200 VAC, 50 Hz for 1 min (at sea level)
Insulation
Resistance
500 Megaohms min
Contact Resistance
(connectors only)
20 milliohms max (Center)
10 milliohms max (Outer, Plug)
10 milliohms max (Outer, Receptacle)
Durability 30 cycles - standard receipt (Styles A,
B)
Disengagement
Force
2N min perpendicular
4N min orthogonal
Center Contact
Retention force
0.15N min
Tape/Reel
Packaging
(receptacle)
12mm carrier per EIA-481
Operating
Temperature
40°C to + 90°C
Table 4-3: U.FL Connector Specifications (Cont.)
Parameter Specifications