Technical information

Chapter 5: JAVA API
July 15, 2008 G24 KJAVA Users Guide 5-7
Temperature
Temperature measurement is mapped from 0-255 A2D units to Celsius.
The actual temperature level (in degrees Celsius) can be derived from table or graphical
representation (see Table 5-3 or Figure 5-1)
Table 5-3: A/D Value to Temperature Conversion
Temperature
(
°C)
A2D
units
Temperature
(
°C)
A2D
units
Temperature
(
°C)
A2D
units
-30 229 4 114 38 43
-29 226 5 111 39 41
-28 223 6 108 40 40
-27 219 7 105 41 39
-26 216 8 102 42 38
-25 213 9 100 43 37
-24 210 10 97 44 36
-23 206 11 94 45 34
-22 203 12 92 46 33
-21 199 13 89 47 32
-20 196 14 87 48 31
-19 192 15 84 49 31
-18 189 16 82 50 30
-17 185 17 79 51 29
-16 182 18 77 52 28
-15 178 19 75 53 27
-14 175 20 73 54 26
-13 171 21 71 55 26
-12 168 22 69 56 25
-11 164 23 67 57 24
-10 160 24 65 58 23
-9 157 25 63 59 23
-8 153 26 61 60 22
-7 150 27 59 61 21
-6 146 28 57 62 21
-5 143 29 56 63 20
-4 140 30 54 64 20
-3 136 31 52 65 19
-2 133 32 51 66 19
-1 130 33 49 67 18
0 127 34 48 68 18
1 123 35 47 69 17
2 120 36 45 70 17
3 117 37 44