Example
+MIOD: (00000000-11111111),(0,1),( 00000000-11111111)
AT+MIOD=00010000,0 // Set IO pin #5 to be output.
OK
AT+MIOD?
+MIOD: 111011111 // Pins 1-4 and 6-8 are input. Pin 5 is output.
OK
AT+MIOD=00001111,0 // Set IO pins 1-4 to be output level mode.
OK
AT+MIOD=11110000,1 // Set IO pins 5-8 to be input level mode.(Default settings).
OK
AT+MIOD?
+MIOD: 11110000 // Pins 1-4 output pins, 5-8 input pins.
OK
+MMAD, Query and Monitor ADC Value
This command intends to query and monitor ADC value.
This command returns the current ADC values for the requested channel. The values received
from the first 3 converters represent the DC voltage levels of the input to pins 37, 43 and 47 on
the 70 pin connector.
The returned value is a multiplication of the input level by 100 (e.g. input level of 1.56V will
return 156).
The 4
th
converter functions as a temperature sensor which its values are pure numbers that should
be converted according to conversion table (Table 3-125).
The 5
th
converter functions as an input voltage monitor of the G24.
The returned value is a multiplication of the input level by 100 (e.g. input level of 1.56v will
return 156).
Command
Type Syntax Response/Action Remarks
Set
AT+MMAD=<Conver
ter number>[,
[<Report>],[<Rate>],[
<Low>],[<High>]]
+MMAD:<Converter
Number>,<Converted Value>
OK
or:
+CME ERROR: <err>