User`s guide

102
Function Key Descriptions
F6 - SECURE OPTIONS This option will be active only if the current radio is capable of Secure
operation and the Secure Hardware Equipped field on this screen is set to Yes.
Brings up a screen where you can modify Radio wide Secure option
settings.
F7 - EMER OPTIONS
(Emergency Options)
This option will be visible only if the current radio codeplug supports
Emergency features. Brings up a screen where you can edit Radio wide
Emergency feature options such as alarms and delays.
F9 - MORE OPTIONS Brings up a screen where you can view and modify additional Radio
wide options.
Field Definitions
Minimum Volume This field will be visible for Portables only. Use the UP/DOWN arrow keys
to select the desired volume level. This is the minimum volume level
the radio will use. If the radio’s physical volume setting is above the
desired level you specify in this field, the actual physical volume
setting will be used. Otherwise, the minimum volume you specify here
will be used. Valid entries range from 0 (zero) to 255.
Alert Tones Use the UP/DOWN arrow keys to enable/disable the radio’s Alert
Tones.
Alert Tone Vol Offset (db) This field will be visible for Portables only, and only when the Alert Tones
field is set to Enabled. Use the UP/DOWN arrow keys to select the Alert
Tone Volume Offset that the radio will use. This is the value by which
the alert tone volume will be raised or lowered with reference to the
current user-selected volume. This offset can range from -26 dB to +25
dB in 1-dB increments.
Self Test Alert Tone This field will be visible only and if the Alert Tones field is set to Enabled.
Use the UP/DOWN arrow keys to enable/disable the Power-Up Self Test
Alert Tone. If this feature is enabled, an alert tone will sound each time
the radio is turned on and self-test is completed.
Min Alert Tone Volume This field will be visible for Mobiles only, and only when the Alert Tones field
is set to Enabled. Use the UP/DOWN arrow keys to select the desired
volume level. This is the minimum alert tone volume level the radio
will use. If the volume setting is above the level you specify, the actual
volume setting will be used to sound an alarm. Otherwise, the
Minimum Alert Tone Volume you specify here will be used. Valid
entries range from 0 (zero) to 255.
Low Battery Tx Chirp This field will be visible for Portables only. Use the UP/DOWN arrow keys
to enable/disable this Low Battery alert tone. If this field has been set
to Enabled and a low battery condition is detected during transmit,
the radio will sound a beep immediately after the PTT button is
released.