Service manual
5. Use a static-safeguarded workstation, which can
be accomplished through the use of an anti-static
kit (Motorola part number 01-80386A82). This kit
includes a wrist strap, two ground cords, a static-
control table mat and a static-control floor mat. For
additional information, refer to Service and Repair
Note SRN-F1052, “Static Control Equipment for
Servicing ESD Sensitive Products,” available from
Literature Distribution.
Motorola
Literature Distribution
2290 Hammond Drive
Schaumburg, IL 60173
(708) 576-2826
When these items are not readily available,
observing the following techniques will minimize
chance of damage.
• If a static-sensitive device is to be temporarily
set down, use a conductive surface for place-
ment of the device.
• Make skin contact with a conductive work sur-
face first and maintain this contact when the
device is set down or picked up.
6. Always wear a conductive wrist strap when servic-
ing this equipment. The Motorola part number for
a replacement wrist strap that connects to the
table mat is 42-80385A59.