Specifications

Motorola Solutions AP-7131N-FGR Access Point Product Reference Guide
8-236
AP7131N>admin(system.radius.proxy)> set
Description:
Sets Radius proxy server parameters.
Syntax:
Example:
admin(system.radius.proxy)>set delay 10
admin(system.radius.proxy)>set count 5
admin(system.radius.proxy)>
For information on configuring Radius proxy server values using the applet (GUI), see Configuring a Proxy Radius Server on page 6-59.
set Sets Radius proxy server parameters.
delay Defines retry delay time (in seconds) for the proxy server. The minimum value is 5 and
maximum value is 10.
count Defines retry count value for the proxy server. The minimum value is 3 and maximum value
is 6.