Installation guide
Hardware Installation
9
5. Cable the access point using a Power Injector solution (AP-PSBIAS-2P2-AFR) as described in
the following:
a. Connect an RJ-45 CAT5 Ethernet cable between the network data supply (host) and the
Power Injector’s Data In connector.
b. Connect an RJ-45 CAT5 Ethernet cable between the Power Injector’s Data & Power Out
connector and the AP-6511 access point.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and access
point does not exceed 100 meters (333 ft). The Power Injector has no On/Off power
switch. The Power Injector receives power as soon as AC power is applied. For more
information, see “
Power Injector System” on page 5.
6. Verify the behavior of the AP-6511 access point LEDs. For more information, see “
LED
Indicators
” on page 14.
7. The AP-6511 is ready to configure. For information on basic access point device
configuration, see “
Defining a Basic AP-6511 Configuration” on page 15.
2.6 Telco Box Installation
For Telco Box installations, the AP-6511 is installed directly over the standard wall plate supplying
Ethernet. All cabled electrical connections are mode within a recessed well in the housing of the
AP-6511 access point.
To install the AP-6511 access point over a Telco Box: