User manual

SM User Manual January 2004
Software Release 4.1
Figure 39: IP Configuration screen, NAT disabled, local accessibility
LAN1 Network Interface Configuration, IP Address
The operator enters the non-routable IP address that will be associated with the Ethernet
connection on this module. (The default IP address from the factory is 169.254.1.1.) If the operator-
assigned IP address is forgotten, then the operator must both
1. physically access the module.
2. use an override plug to electronically access the module configuration parameters at
169.254.1.1. See Overriding IP Address and Password Setting on Page 73.
LAN1 Network Interface Configuration, Subnet Mask
The operator enters an appropriate subnet mask for the module to communicate on the network.
The default subnet mask is 255.255.255.0. See General IP Addressing Concepts on Page 66.
LAN1 Network Interface Configuration, Gateway IP Address
The operator enters the appropriate gateway for the module to communicate with the network. The
default gateway is 169.254.0.0. See SM Module Address Assignment on Page 68.
8.3.2 IP Configuration Buttons with NAT Disabled
Regardless of whether NAT is enabled, the IP Configuration page provides the following buttons:
Save Changes
When the operator clicks this button, any changes that have been made on the IP Configuration
page are recorded in flash memory. However, these changes do not apply until the next reboot of
the module.
Undo Saved Changes
When the operator clicks this button, any changes that have been made but were not committed by
a reboot of the module are undone.
Set to Factory Defaults
When the operator clicks this button, all configurable parameters are reset to the factory settings.
Issue 5 Page 93 of 119