17. Monitor this page for the messages Scanning, Syncing, Registering, Registered,
Alignment.
NOTE: If the SM does not register with the AP, ensure that both modules are
configured to the same color code in the Configuration page of each. In
Release 4.0 and later releases, the Expanded Stats page of the AP provides a link
to the Reg Failed SMs page, where the cause of a registration failure may be
found.
18. Resume slight movements of the module
19. When the best achievable values are simultaneously displayed on the Status page, lock
the module into position.
NOTE: If any of these values is not achieved, the SM may be operational but
manifest occasional problems.
7.5 VERIFYING SYSTEM PERFORMANCE
To verify the performance of the Canopy system after the SMs have been installed, perform the
following steps:
Procedure 15: Verifying system performance
1. Access the web-based interface for the AP (by opening
http://<ip-address>, where the
<ip-address> is the address of the individual module).
2. In the menu on the left-hand side of the web page, click on GPS Status.
3. Verify in the Satellites Tracked field that the AP is seeing and tracking satellites. (To
generate the timing pulse, the module must track at least 4 satellites.)
4. Verify that the Antenna Status field displays the value OK.
5. Access the Status Page of the SM.
6. Verify that the SM is still registered to the AP.
7. Access the Configuration page of the SM.
8. Note the frequency that is selected in the Custom RF Frequency Scan Selection List
field.
9. Access the Configuration page of the AP.
10. Verify that the frequency that is selected in the RF Frequency Carrier field is the same as
noted above.
11. Access the AP Eval Data page of the SM.
12. Verify that the AP is shown in the Sector ID field.
Issue 5 Page 80 of 119