User manual
SM User Manual January 2004
Software Release 4.1
For a description of interactions between settings of these types of passwords, see
Display-Only Access on Page 88 and Full Access on Page 88.
NOTE: If the operator forgets either the password or the IP address for the module, a
Canopy system override plug can be used to regain access. For details, see
Overriding IP Address and Password Setting on Page 73.
2. Populate the Site Name, Site Location, and Site Contact fields. This is for only
information purposes. See
• Site Name on Page 91.
• Site Contact on Page 91.
• Site Location on Page 91.
7.4 INSTALLING THE SM
NOTE: When power is applied to a Canopy module or the unit is reset on the web-based interface,
the module requires approximately 25 seconds to boot. During this interval, self-tests and other
diagnostics are being performed.
To install the Canopy SM, perform the following steps:
Procedure 14: Installing the SM
1. Remove the base cover of the SM. (See Figure 29 on Page 69.)
2. In the powered down state, attach the cables to the SM.
(See Cabling the SM on Page 70 and Figure 30 on Page 77.)
Computer
outside wall
Ethernet cable
300SS
ground
system
Ethernet cable
10 AWG
CU wire
SM
to NIC
24 VDC to
Canopy
wall adapter
Figure 30: SM and computer wiring
3. Choose the best mounting location for your particular application.
4. Optionally, attach the SM to the arm of the Canopy Passive Reflector dish assembly as
shown in Figure 31.
Issue 5 Page 77 of 119