User manual

SM User Manual January 2004
Software Release 4.1
3. Set the Frame Timing Pulse Gated parameter on the Configuration page of the collocated
SM to Enable. See Frame Timing Pulse Gated on Page 89.
NOTE: This setting prevents interference in the event that the SM loses sync.
7.3 CONFIGURING THE SM
To put configuration changes into effect in any case, the operator must:
1. Make the change(s) on the web page of the module.
2. Click the Save button to temporarily save the change(s).
3. Click the Reboot button to reboot the module and implement the change(s).
To configure the SM, the operator must manually set each parameter. (No Quick Start page is
available.)
7.3.1 Configuration from the Factory
From the factory, the SM is configured to not transmit on any frequency. This configuration ensures
that an operator does not accidentally turn on an unsynchronized SM.
Site synchronization of SMs is required because
Canopy modules
transmit or receive, but not at the same time.
use TDD (Time Division Duplexing) to distribute signal access of the downlink and
uplink frames.
When one SM transmits while another receives signal, the transmitting module may
interfere with or desense the receiving module. In this context, interference is self-
interference (within the same Canopy network).
7.3.2 GUI Access Difficulty
Proxy settings in the web browser may prevent access to the Canopy GUI (graphical user
interface). This can occur when the computer has used a proxy server address and port to
configure a Canopy module. In this case, perform the following procedure to toggle the computer to
not use the proxy setting.
GUI Access Procedure
Perform the following steps to access the GUI of this module:
Procedure 11: Bypassing proxy settings to gain access module web pages
1. Launch Microsoft Internet Explorer.
2. Select Tools Internet Options Connections LAN Settings.
3. Uncheck the Use a proxy server… box.
NOTE: If an alternate web browser is used, the menu selections differ from the above.
Issue 5 Page 75 of 119