User manual
SM User Manual January 2004
Software Release 4.1
Table 12 identifies by MAC address whether a module auto-senses the Ethernet cable type.
Table 12: Module auto-sensing per MAC address
Module Type
MAC Address (ESN) of
Non Auto-sensing
Module
MAC Address (ESN) of
Auto-sensing Module
2.4-GHz modules (no ESNs) (all ESNs)
5.2 Modules ≤ 0a003e0021c8 ≥ 0a003e0021c9
5.7 Modules ≤ 0a003ef00f79 ≥ 0a003ef00f7a
Where a non auto-sensing module is used
• use an RJ-45 straight-thru cable to connect to a NIC (network interface card).
• use an RJ-45 crossover cable to connect to a hub, switch, or router.
Where the Canopy AC wall adapter is used
• the +V is +11.5 VDC to +30 VDC, with a nominal value of +24 VDC.
• the maximum Ethernet cable run is 328 feet (100 meters).
7.2.2 Recommended Tools
The following tools may be needed for cabling the SM:
• RJ-45 crimping tool
• electrician scissors
• wire cutters
• cable testing device.
Issue 5 Page 71 of 119