User manual

SM User Manual January 2004
Software Release 4.1
Object Name Value Syntax Operation Allowed
linkOutOctets Counter32 monitor
linkOutQLen Gauge32 monitor
linkOutUcastPkts Counter32 monitor
linkRegCount Integer monitor
linkReRegCount Integer monitor
linkRSSI Integer monitor
linkSessState Integer monitor
linkSpeed Gauge32 monitor
linkTestAction Integer manage and/or monitor
linkTestDuration Integer manage and/or monitor
linkTestError DisplayString monitor
linkTestLUID Integer manage and/or monitor
linkTestStatus DisplayString monitor
linkTimeOut Integer monitor
maxDwnLinkIndex Integer monitor
maxRange Integer manage and/or monitor
numCtlSlots Integer manage and/or monitor
numCtlSlotsReserveHigh Integer manage and/or monitor
numCtrSlot Integer monitor
numCtrSlotHi Integer monitor
numDAckSlots Integer manage and/or monitor
numUAckSlots Integer manage and/or monitor
PhysAddress PhysAddress monitor
privateIp IpAddress manage and/or monitor
radioSlicing Integer monitor
radioTxGain Integer monitor
regCount Integer monitor
regTrap Integer manage and/or monitor
rfFreqCarrier Integer manage and/or monitor
Issue 5 Page 37 of 119