User guide

434
pmp-0229 (Mar 2013)
Managing Module Access by Passwords Securing Your Network
Pin 1 white / orange Pin 1
Pin 2 white / green Pin 2
Pin 3 white / blue Pin 3
Pin 4 green Pin 6
Pin 5 blue Pin 5
Pin 6 orange Pin 4
Figure 150: RJ-11 pinout for the override plug
Using the Override Plug
IMPORTANT!
While the override plug is connected to a module, the module can neither
register nor allow registration of another module.
To regain access to the module, perform the following steps.
Procedure 35: Regaining access to a module
1. Insert the override plug into the RJ-11 GPS utility port of the module.
2. Power cycle by removing, then re-inserting, the Ethernet cable.
RESULT: The module boots with the default IP address of 169.254.1.1, password
fields blank, and all other configuration values as previously set.
3. Wait approximately 30 seconds for the boot to complete.
4. Remove the override plug.
5. Set passwords and IP address as desired.
6. Change configuration values if desired.
7. Click the Save Changes button.
8. Click the Reboot button.