User guide
Canopy System User Guide Managing Module Access by Passwords
pmp-0229 (Mar 2013)
433
• the current user's own account.
• the last remaining account of ADMINISTRATOR level.
Overriding Forgotten IP Addresses or Passwords on AP,
SM, or BH
A small adjunctive product allows you to temporarily override some AP/SM/BH settings and
thereby regain control of the module. This override plug is needed for access to the module in any
of the following cases:
• You have forgotten either
o the IP address assigned to the module.
o the password that provides access to the module.
• You want local access to a module that has had the 802.3 link disabled in the Configuration
page.
You can configure the module such that, when it senses the override plug, it responds by either
• resetting the LAN1 IP address to 169.254.1.1, allowing access through the default
configuration without changing the configuration, whereupon you will be able to view and
reset any non-default values as you wish.
• resetting all configurable parameters to their factory default values.
Acquiring the Override Plug
You can either purchase or fabricate an override plug as follows. To purchase an override plug for
a nominal fee, order the plug at
http://www.best-tronics.com/cambium.htm
. To fabricate an override plug, perform the following
steps.
Procedure 34: Fabricating an override plug
1. Install an RJ-11 6-pin connector onto a 6-inch length of CAT 5 cable.
2. Pin out all 6-pins.
3. Short (solder together) Pins 4 and 6 on the other end. Do not connect any other
wires to anything. The result should be as shown in
4. Figure 150.