401
19. Connect an Ethernet cable to the other Ethernet jack of the 600SS and to the power
adapter.
20. Replace the cover of the 600SS.
21. Connect the power supply to a power source.
22. Connect the Ethernet output from the power supply to the Ethernet port of your laptop.
23. Climb your ladder to the SM.
24. Launch your web browser.
25. In the URL address bar, enter 169.254.1.1.
26. If the browser in your laptop fails to access the interface of the SM, perform the following
steps:
a. Insert your override plug into the RJ11 GPS utility port of the SM.
NOTE: An override plug is shown in Figure 138.
Figure 138: Override plug
b. Remove and reinsert the RJ45 Ethernet cable connector at the SM.
NOTE: This triggers a power cycle, which causes the SM to reboot.
c. Wait for the reboot to conclude (about 30 seconds).
d. When the reboot is finished, remove the override plug.
e. In the left-side menu of the SM interface, click Login.
f. Consistent with local operator policy, reset both the admin and the root user
passwords.
g. In the left-side menu, click Configuration.
h. Click the IP tab.
i. Consistent with local operator practices, set an
IP Address
Subnet Mask
Gateway IP Address
j. Click the Save Changes button.
k. Click the Reboot button.
27. As described under Adding a User for Access to a Module on Page 430, log in as either
admin or root on the SM.
28. Configure a password for the admin account and a password for the root account.
29. Log off of the SM.
30. Log back into the SM as admin or root, using the password that you configured.
31. For coarse alignment of the SM, use the Audible Alignment Tone feature as follows:
a. In the left-side menu of the SM interface, click Configuration.
b. Click the General tab.
c. Set the 2X Rate parameter in the SM to Disabled.