User guide
Canopy System User Guide Configuring a BH Timing Master for the
Destination
pmp-0229 (Mar 2013)
335
Radio Frequency Carrier
Specify the frequency for the BHM to transmit. The default for this parameter is None. (The
selection labeled Factory requires a special software key file for implementation.)
In a 5.7-GHz BHM, this parameter displays both ISM and U-NII frequencies. In a 5.2-GHz BHM,
this parameter displays only ISM frequencies. For a list of channels in the band, see Considering
Frequency Band Alternatives on Page 134.
Alternate Frequency Carrier 1
If your network operates in a region in which DFS shutdown capability is required, and you do not
see this parameter, perform the following steps:
1. Click the General tab.
2. Set the Region Code parameter from its drop-down list.
3. Click the Save Changes button.
4. Click the Reboot button.
5. Click the Radio tab.
From the drop-down list, select the frequency that the BHM should switch to if it detects a radar
signature on the frequency configured in the Radio Frequency Carrier parameter. See Radar
Signature Detection and Shutdown on Page 127.
Alternate Frequency Carrier 2
From the drop-down list, select the frequency that the BHM should switch to if it detects a radar
signature on the frequency configured in the Alternate Frequency Carrier 1 parameter. See
Radar Signature Detection and Shutdown on Page 127.
Color Code
Specify a value from 0 to 254. For registration to occur, the color code of the BHM and the BHS
must match. The default setting for the color code value is 0. This value matches only the color
code of 0 (not all 255 color codes).
RECOMMENDATION:
Note the color code that you enter. Ensure that you can readily associate this
color code both with the module and with the other data that you store about the
module.